Venturi Meters • Classical – Insert – Short Form ASME/ISO Standards

Features

Performance Specifications

Features

• Suitable for pipe sizes from:
1/2″(13mm) to 48″(1200mm)

• Integral transmitter mount 3 or 5 valve manifold
(Option – IT3V)

• Mass flow measurements with dynamic process
compensation for pressure, temperature and DP with
multivariable transmitter

• End connections:
– Threaded (1/2″ to 3″)
– Insert Types (4″ to 30″)
– Butt-weld and flanged
(up to 2500psi/165 Bar)

• Insert styles are designed to be installed between
existing flanges (Series 200)

• Low Permanent Pressure Loss (PPL). High energy
savings, low pumping costs (1/3 of orifice plate)

• Design Standards: ASME/MFC-3M,ISO-5167,
ANSI B31.1 and BS-7045

• Materials: CS, SS, Alloy 20, Chrome Moly, Monel,
Hastelloy, Duplex SS, etc.

Performance Specifications

Accuracy:
±1% of rate – uncalibrated
±0.5% of rate – calibrated
±0.25% of rate – calibrated
(combined with DP transmitter)
Repeatability:
±0.1% of rate
Process Temperature:
Up to 2000°F (1100°C)
Pressure Rating:
Up to 3000psi (200Bar)
Minimum Reynolds Number:
50,000 Rd
Permanent Pressure Loss (PPL):
5 to 14% of DP (depends on pipe size and Beta ratio)
Turn Down Ratio (TDR):
10 to 1 and higher with stacked transmitters
Discharge Coefficient:
Stable over the entire flow range
Maximum Viscosity:
500 CP – CentiPoise (MPAS)